919870255519 919870255519
IDDC Engineers Pvt. Ltd.

Pile Integrity Testing Services


INTEGRITY TESTING OF PLIES BY LSIT(TDR) METHOD

The Test -
The Transient Dynamic Response (TDR) method is a reliable, simple, easy and more versatile way of pile integrity data. The equipment is lighter, the heavy vibrator is replaced by a load cell weighing less than 1 kg. Other components include an oscilloscope, velocity transducer (geophone), microprocessor and X Y plotter. The TDR involves impacting the pile / section head with a hand held instrumented hammer and measuring both impact force and pile / section velocity response as a function of time. The set of Data is processed to yield Mobility / frequency plots. The results can be interpreted to give information about both the pile / section shaft integrity and the surrounding soil conditions.

IDDC ENGINEERS PVT. LTD. (IDDC) has proven expertize in field of pile testing. We have completed projects for pile testing all
over India.


Some of the prestigious projects are -

  • Barh super thermal power project for NTPC by Navayuga Engg. Co. Ltd. - 15825 nos. of piles
  • 765 KVA transmission line project for PGCIL by Navayuga Engg. Co. Ltd. - 320 Nos. of piles.
  • 400 KV Mundra - Jetpur DC transmission line for PGCIL by RVR Projects Pvt. Ltd. - 368 Nos. of piles.
  • For various clients at different locations all over India - Over 1000 Nos. of piles.